Communication between the SuperK control room and the radon hut is established over a 2-km long 6-conductor cable (3 twisted pairs) through the Atotsu tunnel. 4 of the conductors (2 pairs) are used for the serial port link between the PLC controller in the radon hut and sukslc (slow control computer) in the SK central hut. The other 2 conductors (1 pair) are used for a voice connection with mine phones (Femco phones).
| 2km cable | Blackbox cable | function |
|---|---|---|
| orange | green | BB XMT+ |
| orange-white | white | BB XMT- |
| green | red | BB RCV+ |
| green-white | black | BB RCV- |
| blue | n/a | Femco phone - |
| blue-white | n/a | Femco phone + |
| Blackbox configuration in center hut | |
|---|---|
| DCE/DTE switch: | DCE |
| DIP switches: |
1 = OFF 2 = OFF 3 = ON 4 = OFF 5 = OFF 6 = ON 7 = OFF 8 = OFF |
| 2km cable | Blackbox cable | function |
|---|---|---|
| orange | red | BB RCV+ |
| orange-white | black | BB RCV- |
| green | green | BB XMT+ |
| green-white | white | BB XMT- |
| blue | n/a | Femco phone - |
| blue-white | n/a | Femco phone + |
| Blackbox configuration in radon hut | |
|---|---|
| DCE/DTE switch: | DTE |
| DIP switches: |
1 = OFF 2 = OFF 3 = ON 4 = OFF 5 = OFF 6 = ON 7 = OFF 8 = OFF |