Quick Manual for the OD HV Supply

front panel of a OD High Voltage supply (LeCroy model 1454)
How to manually disable or enable a HV channel
- Turn the key switch on lower left side to "LOCAL" position.
Note: Please be careful not to overturn the key further to
the "OFF" position!!
- With the cursor keys (next to LCD display) select the desired HV channel number.
- To disable the selected channel push the DISABLE button on right side of panel.
- To re-enable the selected channel push the ENABLE button on right side of panel.
- When finished, turn the key switch back to "REMOTE" position (default).
How to change the voltage setting of a HV channel
- Turn the key switch on lower left side to "LOCAL" position.
Again, to emphasize: Please be careful not to overturn the
key further to the "OFF" position!!
- With the cursor keys (next to LCD display) select the desired HV channel number,
then move to "Target_V"value of that channel.
- Make a note of the current "Target_V" (target voltage) setting before you change anything.
- It's highly recommended to DISABLE the channel before you change the settings.
- Push the SELECT button (located below the cursor buttons).
- With curser and numerical keypad buttons (or INCREMENT, DECREMENT, etc.) modify the target voltage to
the desired setting.
- Push the ENTER button (lower right of numerical keypad) to make the actual change.
- Push the ENABLE button to switch the selected channel with the new HV setting.
- If you like to change the target voltage again, repeat steps 3 - 7.
- If you're done with your tests, change the "Target_V" value back to the original setting.
- Make sure the channel is enabled again.
- Turn the key switch to "REMOTE" position (default).
HGB,
posted 11/27/2000, last edited 8/26/2005.